Analog Laser Power Probe Specifications

dials

Model

Power Range

Wavelength

Damage
Threshold
(at max
Power)

Exposure Time

Watts/
Division

Absorbing Head

Overall Length (cm)

Weight (gm)

Accuracy §

Repeatability

P20Y

2-20W

900-1250nm*

3000W/cm2

30 sec.

0.2

4.58 x 2.54 cm
(1.8" x 1")

22

89

+/-5%

+/-1.5%

P50Y

5-50W

900-1250nm*

3000W/cm2

20 sec.

0.5

4.58 x 2.54 cm
(1.8" x 1")

22

98

+/-5%

+/-1.5%

P100Y

10-100W

900-1250nm*

3000W/cm2

20 sec.

1

5.08 x 3.18 cm
(2"x1.25")

22

120

+/-5%

+/-1.5%

P100C

10-100W

8µ - 11µ

10,000W/cm2

20 sec.

1

5.08 x 3.18 cm
(2"x1.25")

22

120

+/-5%

+/-1.5%

P200Y

20-200W

900-1250nm*

2500W/cm2

20 sec.

2

5.08 cm dia.
(2" dia.)

22

157

+/-5%

+/-1.5%

P200C

20-200W

8µ - 11µ

7000W/cm2

20 sec.

2

5.08 cm dia.
(2" dia.)

22

157

+/-5%

+/-1.5%

P500Y

50-500W

900-1250nm*

2000W/cm2

20 sec.

5

5.08 cm dia.
(2" dia.)

22

183

+/-5%

+/-1.5%

P500C

50-500W

8µ - 11µ

4000W/cm2

20 sec.

5

5.08 cm dia.
(2" dia.)

22

183

+/-5%

+/-1.5%

P1000Y

100-1000W

900-1250nm*

1750W/cm2

20 sec.

10

6.35 cm dia.
(2.5" dia.)

22

287

+/-5%

+/-1.5%

P1000C

100-1000W

8µ - 11µ

2500W/cm2

20 sec.

10

6.35 cm dia.
(2.5" dia.)

22

287

+/-5%

+/-1.5%

P2000Y

200-2000W

900-1250nm*

1200W/cm2

20 sec.

20

7.62 cm dia.
(3" dia.)

22

522

+/-5%

+/-1.5%

P2000C

200-2000W

8µ - 11µ

1500W/cm2

20 sec.

20

7.62 cm dia.
(3" dia.)

22

522

+/-5%

+/-1.5%

P4000Y

400-4000W

900-1250nm*

900W/cm2

20 sec.

25

8.89 cm dia. x 4.6cm
(3.5" x 1.9")

28

753

+/-5%

+/-1.5%

P4000C

400-4000W

8µ - 11µ

1100W/cm2

20 sec.

25

8.89 cm dia.
(3.5")

28

753

+/-5%

+/-1.5%

P10KY

500-5,000W
1000-10kW

900-1250nm*

750W/cm2

20 sec.
10 sec.

50
100

8.89 cm dia. x 5.6 cm
(3.5" x 2.2")

28

1144

+/-5%

+/-1.5%

P10KC

500-5,000W
1000-10kW

8µ - 11µ

900W/cm2

20 sec.
10 sec.

50
100

8.89 cm dia.
(3.5")

28

1144

+/-5%

+/-1.5%

 

 

 

 

Y type probe wavelength range - These probes are calibrated at 8-11µ as well, but have a lower damage threshold for this range than the C type probes.  Calibration for any wavelength between 250nm – 2500nm is available upon request with an NIST certificate.

Damage Threshold - Moving the probe during exposure will increase (up to double) the damage threshold compared to the numbers shown for a stationary probe. To achieve this increase, the head must be moved in a circular motion so that the laser beam does not strike any one area continuously for more than 1.5 seconds.

Accuracy and Exposure Time -  The accuracy and repeatability of the Power Probes partly depends on the accuracy of the exposure time. The average accuracy of exposures (hand held) has been found to be 0.2 seconds. This amounts to a 1% error for a 20 second exposure time. Many lasers are equipped with a shutter that can produce an exact time exposure.




 